Equip a system of water underfloor heating in a country house and it's time to lay the insulation substrate? Agree that among the variety of offers of insulating materials offered by manufacturers, it is sometimes not easy to make the right choice.
We will help determine which insulation for a warm water floor is better. Together with you we will deal with all the intricacies of the assembly of heat-insulating systems. We study the characteristics of popular materials, evaluate the key advantages and disadvantages.
Independent home masters with us will find installation instructions. To make it easier to navigate in the assortment offered by the building materials market, we selected rollers with recommendations on the choice of insulation and styling.
The need for thermal insulation system
In any installation instructions for a water heated floor for independent masters, it is indicated that it is necessary to use a heater.
The insulation layer during the arrangement of the water floor performs several significant functions. It helps not only to ensure uniform heating of the room, but also, acting as a heat shield, can significantly reduce the energy loss of the system.
The screed, laid on top of the insulating layer, acquires the properties of an integral heat transfer element having a large surface area.
The main purpose of the insulating layer is to evenly distribute heat in the heated room, preventing it from leaking through the floor slabs
Due to the uniform distribution of energy, an ordered convection heat flow begins to move at the same speed and in one direction. As a result, evenly distributed heat waves will not form cold and hot areas on the floor, creating the most comfortable conditions for households.
In addition, due to the direction of the flow of warm air at one rate, it is possible to reduce the cost of electricity for the operation of the system, while maintaining its power unchanged.
Modern heat-insulating mats are equipped with convenient snaps in the form of bosses, with the help of which laying and subsequent fixation of pipes can be done quickly and at the same time reliably.
Image Gallery
Photo from
In the construction of a heat-insulating layer for water floor heating systems, rolled soft and hard plate materials are used. Roll-ups are easier to install, but less efficient in terms of heat engineering criteria.
Among the plate options for thermal insulation, extruded polystyrene foam is most often used, the structure of which practically eliminates the absorption and retention of moisture
Organization of the insulating component of the non-extruded polystyrene floor system, i.e. polystyrene foam, requires a mandatory waterproofing device on top of the layer, which is not necessary to do using the material obtained by extrusion
To facilitate the installation of the floor heating pipeline, it is better if there is a marking on the outer surface of the plates
The simplest and most convenient option for warming is now polystyrene plates with a convex relief, performing a lot of useful functions
Lugs of polystyrene mats allow you to clearly and quickly install pipes of the underfloor heating according to the chosen scheme, play the role of marking
The relief of polystyrene boards serves as a support for plywood or gypsum boards when performing dry screed
In areas within which it is impossible to comply with the calculated step during installation, pipe insulation is used that excludes zonal surface overheating
Roll underlay for underfloor heating
Styrofoam insulation
Styrofoam insulation
Factory marked foil plates
Polystyrene insulation mats with bosses
Installation of pipes with the required pitch
Formation of distance for dry internship
The use of penoflex for pipes
Types of insulation under a water floor heating
There are many options for insulation for a floor water heating system in the modern market. The choice of substrate thickness is limited only by the material capabilities of the owner and the technical parameters of the room.
Absolutely all heat-insulating materials impede the movement of sound waves through its thickness, and therefore are characterized by high rates of sound absorption.
If there is a heated room under the base base, enough insulation is 10-12 mm thick, if the basement or soil, a substrate of 30 mm or more is required
Regardless of the embodiment, special requirements are imposed on the heat-insulating material:
- it must have a low coefficient of thermal conductivity;
- perceive the load created by water-filled pipes;
- withstand the load laid on top of the pipeline screed;
- be resistant to dynamic influences that may occur during operation of the system, and after reducing the pressure, it should take its original form.
To achieve the desired effect allows the use of insulation material, the density of which is at least 35 kg / m3.
Option # 1 - Insulating boards
In rooms where the ceiling height reaches 260 centimeters and above, you can safely give preference to heaters on a rigid polymer base.
Styrofoam or Styrofoam. The basis for the manufacture of heat-insulating boards can be foam or expanded polystyrene.
The first option was created in a non-extrusion way, between its polymer cells there are channels for the passage of air and steam. The foam is characterized by low specific gravity, as well as high vapor permeability.
In the manufacture of expanded polystyrene, the extrusion method is used, due to which the material cells are firmly sintered by the walls with each other. The vapor permeability of the insulation due to this is practically zero. But it has high strength and the ability to withstand significant mechanical loads.
The specific heat capacity of expanded polystyrene is slightly higher than that of expanded polystyrene. In the first case, it is equal to 1.34 kJ / (kg ° C), in the second it is calculated 1.26 kJ / (kg ° C). The difference is small, but in the calculations it can significantly affect the total thickness of the floor heating system.
The standard size of Penoplex thermal insulation sheets, for example, 120 cm × 240 cm. GOST No. 15588-86 regulates width from 50 cm to 130 cm, length from 90 cm to 500 cm.
The density of foamed polystyrene is 150 kg / m³, the same foam characteristic is 125 kg / m³. Depending on the specifics of production and the properties invested by manufacturers in the products, the characteristics of the materials may vary.
Due to the unique composition, polystyrene plates act as good noise insulators, and their permissible load is about 50 kN / sq.m
If you compare both types of material, the foam is disadvantageous in that it is inferior to the extrusion product in terms of density. Due to this, it is less resistant to deformation under the action of mechanical loads.
From this, its thermal insulation properties are significantly reduced. Polyfoam is recommended to be laid in the structures of flooring systems between the logs.
Cork. Often, a cork is used as a heat-insulating substrate for water and electric floors. Due to the special structure, which is a miniature prism of the correct shape, cork insulation is characterized by significant compressive strength, as well as the lack of adhesion to the cement mortar.
Due to the high cost of the material, cork coating is often chosen for residential premises in which the base base is already well insulated. Otherwise, to achieve the desired effect, you will need to purchase a technical cork with a thickness of at least 30 mm, which can significantly “hit the wallet”.
The main advantage of mats made of several layers of glued fibers of cork oak bark is environmental safety.
The only drawback of cork mats is that they are hygroscopic and are also available as single-component heat insulators. And therefore, when laying them, it is necessary to use an additional layer, which will provide vapor and water protection.
Mineral wool. As an alternative affordable option - the use of mineral wool. It is available in the form of a flexible mat or hard plate.
Since when laying in a screed, mineral wool is crushed under weight, which negatively affects its heat-shielding properties, this material is also better to combine with flooring structures assembled from wooden logs.
With the use of mineral wool as a heat-insulating layer, the heat transfer of a water floor heating will be maximum
The only drawback of the material is the presence of penofol in the composition, which carries a danger to human health, and low moisture resistance. But properly executed waterproofing easily eliminates these shortcomings.
Option # 2 - profile systems with guides
Profile systems help facilitate the installation of water circuits. They are created using the technology of hydro-pellet stamping, as a result of which curly protrusions are formed.
Products are of two types: ordinary and laminatedwhich are covered with a vapor barrier film.
Boss or guide grooves are located on the surface of the profile mats in even rows, between which it is convenient to lay heating circuits
The basis for their manufacture is extruded polystyrene foam, which is created by extruding the molten composition through the holes of the extruder.
The polymer base is famous for its resistance to moisture and high mechanical strength. The thickness of the plate itself can vary from 10 to 35 mm. The main thing is that it be proportional to the thickness of the finish screed.
The lateral sides of each plate are equipped with locks, with which it is convenient to carry out the fitting of elements, forming a continuous field devoid of thermoacoustic seams.
The height of the cylindrical protrusions located on the surface of the plates reaches 20-25 mm. This is enough to conveniently place and securely fix water circuits with a diameter of 14 to 20 mm. Tightly planted rows of bosses eliminate the likelihood of a shift in the laid out contours during the pouring of the cement screed.
The only drawback of profile systems is that it is impossible to lay water circuits made of pipes of non-standard diameter in them.
A feature of the installation of profile systems is that after laying the water circuits in them, the structures are poured on top with a small layer of adhesive. And only after a day or two, when the glue is completely dry, the system is put into operation.
Image Gallery
Photo from
Polystyrene plates with bosses
Lock on the edge of the heat insulation plate
Formation of a smooth bend angle of pipes
Assembled underfloor heating
Option # 3 - roll insulation
Roll insulation is chosen for rooms in which the distance to the ceilings is critical. Using thin foil layers with a protective lavsan coating, the thickness of the “pie” can be significantly reduced. The maximum thickness of such a substrate is only 9-12 mm.
The foil layer applied on one side of the insulation reflects thermal radiation well, thereby preventing energy loss.
Roll insulation is equipped with a heat-reflecting shell of lavsan or heat insulation. Thin metallized materials perfectly reflect heat rays, due to which it is possible to safely reduce the thickness of the insulation without fear for a decrease in insulating qualities.
An important requirement when using foil options is that it is impossible to use materials with aluminum foil in the installation of floors with a cement-sand screed. The alkaline environment of the mixture during pouring will simply corrode the aluminum layer.
However, if a protective film is applied over the foil, styling is possible. Use is allowed if the solution is mixed on gypsum, and not on cement powder. Some manufacturers replace the foil layer with lavsan or a polypropylene film, adding metallized inclusions to it.
In an effort to facilitate the installation process, many manufacturers apply a special marking on the foil side of the manufactured roll materials, which serves as a guide for laying the heating circuit
The disadvantage of foil materials is that they reflect heat well, but do not insulate well enough. If the floor is laid over the basement, thin roll solutions are not enough.
Some craftsmen solve the problem by laying hard insulation mats not in one layer, but in two. But at the same time, the sheets are placed so that the seams of the lower substrate are overlapped by the seams of the upper. This minimizes heat loss.
Features of laying insulation
The mounting pattern of the substrate depends on the type of materials used. But in any case, it must be placed on the most even surface.
No. 1 - plate laying technology
The substrate constructed of slabs with mounting chamfer is easy to assemble - according to the principle of the designer. Plates are conveniently customized and measured. You can cut the plates to the appropriate dimensions with an ordinary knife.
The ease of laying the substrate is convenient because during installation at any time you can change the configuration of the contours and the length of the pipelines. So that the plates of material during installation and operation do not move relative to each other, their joints are glued with construction tape.
In order to prevent the formation of heat-conducting bridges, the contour seams between adjacent plates are glued with foil tape
The sequence of actions when laying insulating boards:
- Foam plates are laid on a cleaned and leveled base, fixing them using special plastic staples, anchor dowels or planted on an adhesive.
- On top of the laid and stacked plates, a foil layer is lined.
- The upper layer is lined with a reinforcing mesh, on which pipes are subsequently mounted.
If the concrete screed of the base floor is poured with significant deviations from the level or has rough cracks and irregularities, or the concrete slabs are laid with irregularities, it is better to build a frame before laying the substrate. For this, wooden logs are collected from a dry and even beam with a section of 50x50, 50x100 or 100x100 mm.
Logs are placed at an equidistant distance of 60 cm, between them lay cuts of mineral wool or a foam plate
A distance of 60 cm between the lags is considered the best option, because with this "step" does not require the creation of an additional crate. The main thing is that the lags are located in one plane and lie strictly in level.
Thermal insulation boards must be tightly laid between the wooden logs. If there are cracks, they must be blown off with foam.
In laying plates of extruded polystyrene foam, it is necessary to observe some nuances:
Image Gallery
Photo from
Cutting plates of extruded polystyrene
Brick Laying
Installation of damper tape around the perimeter of the room
Waterproofing with factory marking for installation
No. 2 - installation of rolled materials
Laying of the rolled material is carried out on a carefully aligned base and fixed to the base base using tile glue or double-sided tape. Cutting strips of the required size is performed with ordinary stationery scissors.
To compensate for the thermal expansion of the screed, it is recommended to place the foil layer with a slight approach to the wall.
The foil material is placed with the metal side up so that the metallized surface reflects heat in the best way
When laying rolled materials, they are guided by the marking of printed mounting markings. It determines the distance between the contours and facilitates the laying of pipes. Typically, the roll materials at the edges have allowances of foil polymer film for the possibility of joining adjacent paintings.
When laying cuts, special attention is paid to temperature seams. For this, the joints of the laid strips are glued with one-sided construction or metallized tape. If a cork coating is used as the substrate, then before laying it is necessary to take care of reliable vapor and waterproofing.
No. 3 - layout of the installation of mats
The stage preceding the laying of the mats is the arrangement of film waterproofing. After laying it around the perimeter of the room, along the bottom of each wall, stick strips of damping tape.
On the prepared base, the mats are lined, fastening the plates together by means of a castle system. To securely fasten plates of small thickness and light weight, the adhesive method is used and plastic harpoons are used.
Some manufacturers for the convenience of installation complete with mats apply edge strips with which it is convenient to mark the areas of exit from the heating zone
An important point: when laying mats, it is not allowed to use metal fasteners, since it can damage the integrity of not only the heat insulator, but also the waterproofing.
Choosing the best base for a thermal insulation substrate depends on your capabilities. Yes, a good substrate is not cheap. But it will significantly increase the functionality of the equipped system of water floors.
Video # 1. The choice of insulation for cement screed:
Video # 2. A good example of laying mats:
Video # 3. Installation of roll insulation:
In order not to make a mistake in choosing a heater for a water floor, be guided by the technical characteristics of the room, taking into account not only the thickness of the product, but also the maximum allowable compression load.
Properly approaching the choice of a heat insulator and observing all the subtleties of installation, you can create a reliable foundation for arranging a functional floor water system.
Do you want to talk about how to choose and stack a heater under the heating floor at home? Have questions or valuable suggestions? Please write comments in the block below.